Taguchi:Abbreviations: Difference between revisions

mNo edit summary
No edit summary
Line 100: Line 100:
|}
|}


<!---------
===Program===
===Program===
{| class="wikitable sortable"
{| class="wikitable sortable"
Line 112: Line 113:
|}
|}


<!---------
==Parameters==
==Parameters==
{| class="wikitable sortable"
{| class="wikitable sortable"

Revision as of 02:41, 24 August 2010

Extraction

Abbreviation Description
B&D Bligh and Dyer method
SPE Solid-phase extraction method
TLC Thin layer chromatography

Solvent

Abbreviation Description
Ace acetone
AceA acetic acid
ACN acetonitrile
Amm ammonia
AmFo ammonium formate
But butanol
Chl chloroform
ForA formic acid
Hex hexane
IsoP isopropanol
Met methanol
MFo methyl formate
NaAc sodium acetate
PhoA phosphoric acid
TriE triethylamine
W water

Purification

Abbreviation Description Vendor
C18 SP C18 Sep-Pak Waters
DEAEc DEAE cellulose Wako Pure Chemicals
DEAEsA25 EAE sephadex A-25 Amersham Biosciences
GS4B glutathione Sepharose 4B Amersham Biosciences
SiG Silica gel
OHLB Oasis HLB Waters

Liquid Chromatography

Phase

Abbreviation Description
Nor normal
Rev reverse

Program

Abbreviation Description
Gra gradient
Iso isocratic
Lin linear
Ste stepwise

Column

Abbreviation Description Vendor
ACU18 ACQUITY UPLC BEH C18 Waters
APC18 Acclaim PepMap300 C18 LC PACKINGS
DevC30 Deverosil C30 Nomura Chemicals
DevSi60 Deverosil Si60 Nomura Chemicals
HiQ sil HiQ sil KYA TECH
Si60 Si60 Nomura Chemicals
UC18 Unison C18 nano LC column Imtakt
WXBC18 Waters X-Bridge C18 Waters

System

Abbreviation Description Vendor
AU ACQUITY Ultra Performance LC system Waters
HP1100 HP 1100 HPLC system Hewlett-Packard
LC10AD LC-10AD vp micro HPLC system Shimadzu
P305 pump model 305 Gilson
UM Ultimate HPLC system LC Packings
UM3000 UltiMate 3000 nano/cap/micro LC system Dionex

Mass Spectrometry

Ionization

Abbreviation Description
ESI electrospray ionization
FTICR Fourier transform ion cyclotron resonance

MS/MS conditions

Abbreviation Description
MRM multiple reaction monitoring
NLS neutral loss scan
PIS precursor ion scan

Mode

Abbreviation Description
Pos positive
Neg negative

System

Abbreviation Description Vendor
APEX APEX III, FTICR mass spectrometer Brucker Daltonics
LCQ LCQ, ion trap mass spectrometer Thermo Fisher Scientific
LTQ LTQ, ion trap mass spectrometer Thermo Fisher Scientific
LTQ-Orbi LTQ-Orbitrap, mass spectrometer Thermo Fisher Scientific
QTRAP 4000QTRAP, quadrupole-linear ion trap hybrid mass spectrometer Applied Biosystems
Q-TOF II Q-TOF II, quadrapole/time of flight hybrid mass spectrometer Micromass
Q-TOF mi Q-TOF micro, quadrapole/time of flight hybrid mass spectrometer Micromass
Quatro Quattro II, triple-stage quadrupole mass spectrometer Micromass